Specifications

  • Easy to use with English menu
  • Advanced dynamic software
  • Easy to commissioning
  • Large color LCD screen
  • Enough number of steps needed (12 steps)
  • Quickly and accurately detection power of capacitors
  • Normal or fast operation mode selection
  • Connecting three phase, double-phase and single-phase capacitor
  • Connecting shunt reactors
  • Displaying the current and voltage
  • Total current and voltage harmonics
  • Displaying the phase or phases to which connected capacitors
  • Operating system is used in the micro-processor
  • Computer communicated (RS485, MODBUS, RTU)
  • For balance or unbalance operating
  • Measuring temperature
  • Following electrical parameters of three phases at the same time
  • Certificates: CE, UL, ISO
  PR-15D  
         

 


  

Technical Characteristics 
Standard

IEC 55011+A2, IEC 61326

IEC 61000-3-2/3+A1+A2, IEC 61010-1

EN 55011+A2, EN 61326

EN 61000-3-2/3+A1+A2, EN 61010-1

 
Rated Operation Voltage [V] 90-550
Rated Input Voltage [V] 11-300V AC (L-N), 50-520V AC (L-L)
Rated Input Current [A] 5A AC (Min. 11mA, Max. 6A)
Frequency [Hz] 45-65Hz
Power Consumption [VA] Max. 15
Display Liquid Crystal Display with Backlight (4digits)
Output Relays [Steps] 6, 8, 12 (or 14 Without Alarm and Fan Relay)
Necessary CT 1 or 3
CT Primary 1A/ 5A to 10000A
CT Secondary 1A/ 5A
Wiring Input

1 Phases, 2 Wires

2 Phases, 2 Wires

3 Phases, 3 Wires

3 Phases, 4 Wires

Controlling Range 0.800 (Ind) to -0.800 (Cap)
Measurement

Voltage of Phases - V(L1,2,3 – N)

Current of Phases - I(L1,2,3 – N)

THD Current, THD Voltage

Cosφ Value of Phases - Cosφ(1,2,3)

Tanφ Value of Phases - Tanφ(1,2,3)

Power Factor Value of Phases - PF(1,2,3)

Active Powers - ΣP, P1, P2, P3

Inductive Reactive Powers - ΣQ(Ind), Q1(Ind), Q2(Ind), Q3(Ind)

Capacitive Reactive Powers - ΣQ(Cap), Q1(Cap), Q2(Cap), Q3(Cap)

Apparent Powers - ΣS, S1, S2, S3

Temperature

Accuracy 1%±1 Digit
Transmission Speed 300, 600, 2400, 4800, 9600, 19200
Alarm

Over Voltage, Under Voltage, No Voltage,  Over Current,  Current Absent,  

Over Compensate, Under Compensate,   THD Current Error, THD Voltage Error, 

Over Temperature, CT Error, Error Connection

Parity No, Even, Odd
Communications RS485 Modbus RTU
Protection Class IP54
Connector Protection Class IP20
Operating Temperature [ºC] 0ºC +60ºC
Storage Temperature [ºC] -20ºC +60ºC
Humidity [%RH] Max. 95%
Alarm Indication Red Led (Off, Blinking or Fixed)
Mounting Front Panel Mounting
Dimensions [HxDxW] [mm] 144x144x63
Panel Cutout [mm] 138x138

Support

Our Boarding Support Hotline is Available 24 Hours a Day:

  • Mobil: +98 903 112 95 14

Business Hours

Office:

  • Saturday-Wednesday: 8AM to 17PM
  • Thursday: 9AM to 12PM
  • Friday: closed

Warehouse:

  • Saturday-Wednesday: 9AM to 15PM
  • Thursday-Friday: closed

Contact Us

Address: Unit 27, No.495, Laleh Building, Next to Sazman Barnameh St, W Ferdows Blvd, Tehran, Iran

Postal Code: 1483756496

Telefax: +9821 44549854

Email: info@tanirco.com

Website: www.tanirco.com